Optical Time Domain Reflectometry

End users use optical time domain reflectometry to characterize optical-fiber and optical-connection properties in the field. In optical time domain reflectometry, an OTDR transmits an optical pulse through an installed optical fiber. The OTDR measures the fraction of light that is reflected back due to Rayleigh scattering and Fresnel reflection.

By comparing the amount of light scattered back at different times, the OTDR can determine fiber and connection losses. When several fibers are connected to form an installed cable plant, the OTDR can characterize optical-fiber and optical-connection properties along the entire length of the cable plant. A fiber- optic cable plant consists of optical-fiber cables, connectors, splices, mounting panels, jumper cables, and other passive components. A cable plant does not include active components such as optical-transmitters or receivers.



The OTDR displays the backscattered and reflected optical-signal as a function of length. The OTDR plots half the power in decibels (dB) versus half the distance. Plotting half the power in dB and half the distance corrects for round trip effects. By analyzing the OTDR plot, or trace, end users can measure fiberattenuation and transmission loss between any two points along the cable plant. End users can also measure insertion loss and reflectance of any optical connection. In addition, end users use the OTDR trace to locate fiber breaks or faults.

The illustration below shows an example OTDR trace of an installed cable plant. OTDR traces can have several common characteristics. An OTDR trace begins with an initial input pulse. This pulse is a result of Fresnel reflection occurring at the connection to the OTDR. Following this pulse, the OTDR trace is a gradual downsloping curve interrupted by abrupt shifts.

Periods of gradual decline in the OTDR trace result from Rayleigh scattering as light travels along each fiber section of the cable plant. Periods of gradual decline are interrupted by abrupt shifts called point defects. A point defect is a temporary or permanent local deviation of the OTDR signal in the upward or downward direction.

Point defects are caused by connectors, splices, or breaks along the fiber length. Point defects, or faults, can be reflective ornonreflective. An output pulse at the end of the OTDR trace indicates the end of the fiber cable plant. This output pulse results from Fresnel reflection occurring at the output fiber-end face.

OTDR-trace-of-an-installed-cable-plant

Optical Time Domain Reflectometry (OTDR) trace of an installed cable plant.


(back) (top) (next) (return to fiber optic measurement page)

Become a loyal member to our site. It's free!

Enter your E-mail Address
Enter your First Name (optional)
Then

Don't worry — your e-mail address is totally secure.
I promise to use it only to send you Learn-about-electronics.

Site Search

Custom Search




Subscribe to me on YouTube



Translate your page

If English is not your first language you can Translate the text on this page to any one of the languages found in the drop down menu. Select your language from the list for an instant translation.


Looking for something unique for your project? Choose from the drop down menu for quick access to the item you seek.




Related Pages

soldering circuit board

TheSolderBlob.com

Basic Electronics image

Become an Electronics Technician

UnitConversion.org

Convert most anything with this utility

Coaxial cable

Find your wire and cable here!


Sponsored Sites

Sponsor Policy

Adobe Dreamweaver CS5

SBI! Proof

Learn more about SBI here!

Diy-Audio-Guide.com

www.Diy-Audio-Guide.com

www.Home-PC-Help.com

www.Home-PC-Help.com


If you like this site please pay it forward. Donations are welcome.